Setting out and excavation

Placing the house on the site, keeping clear of trees, and digging foundation trenches to the right depth.

What setting out means

Setting out is marking the exact position of the house on the ground before any digging starts. The builder uses the approved plans to find the corners of the building, then marks the lines of the walls with pegs and string lines. Many builders fix the string lines to timber profiles (boards on pegs set a little outside the trench) so the lines can be put back after digging.

A common way to check that a corner is square is the 3-4-5 method: measure 3 m along one line and 4 m along the other; if the corner is square, the distance between those two marks is exactly 5 m. Checking that the two diagonals of a rectangle are equal does the same job.

Be aware that SANS 10400-H does not set rules for how to set out. The methods above are general site practice. What SANS 10400-H does control is where walls may go in relation to trees, and how deep the foundations must be. Those are the parts of this lesson you can look up in the standard.

Keep walls away from trees

Trees draw water out of the soil. On clay sites, soil that dries out shrinks, and swells again when it gets wet, so the walls on it can crack (Annex D, D.5.3). Roots and trunks can also push against structures directly (D.5.2). So the standard sets minimum distances between masonry walls and the centre of tree trunks or shrubs (4.3.2.1.4 and Table 2).

For the outside (perimeter) walls of buildings, Table 2 sets the distance by the tree's mature height (how tall it will be when fully grown):

  • Trees shorter than 8 m: Table 2 gives no figure (it shows a dash).
  • Trees from 8 m to 15 m tall: at least 0,5 m.
  • Trees taller than 15 m: at least 1,2 m.

On clay sites, where drying and wetting soil causes the most trouble, the distances are much bigger and depend on the tree's mature height (4.3.2.1.4):

  • H1 sites: at least 0,75 times the tree's mature height.
  • H2 sites: at least 1,0 times the mature height.
  • H3 sites: at least 1,5 times the mature height.

So on an H2 site, a tree that will grow to 10 m tall must be at least 10 m from the wall. Check the site class (from the previous lesson) before you finalise where the house goes.

Digging the trenches

Once the lines are set out, the foundation trenches are dug along them. A trench for a strip footing (the concrete strip a wall stands on; see the next lesson) must be deep enough for the footing to sit at the depth the standard details (or the engineer's design) require.

On the standard strip footing details for class C, H, R and S sites, the underside of the footing must be at least 400 mm below natural ground level, unless the footing is on rock (SANS 10400-H, Figure 5). Natural ground level (often written NGL) is the level of the ground surface before any digging or filling.

Some sites need deeper footings:

  • On H1, C1 and S1 sites, the stricter "modified normal construction" details show a minimum founding depth of 500 mm, unless the geotechnical report says otherwise (Figures 8 and 10).
  • On some problem soils, the answer is to dig right through the weak layer and found the footing on better soil underneath. The standard calls this a deep strip foundation (Table B.1).

"Founding depth" just means how deep the bottom of the foundation sits. The ground the foundation rests on is called the founding horizon.

When the soil itself has to be fixed

Sometimes the best answer is to improve the ground rather than just make the foundation bigger. SANS 10400-H calls these geotechnical solutions. Examples are (4.3.1.1):

  • digging out the problem soil layer and replacing it with well-compacted, stable material (or putting the same soil back, properly compacted);
  • founding deeper, below the problem layer;
  • compacting the soil where it lies.

A geotechnical solution must be designed by a competent person (geotechnical) (4.3.1.1), who must also inspect the work while it is being done (4.3.1.3). For deep strip foundations on C1, C2, S1 and S2 sites, a competent person (civil engineering or geotechnical) must inspect and approve the founding horizon before concrete goes in (4.3.1.4).

Deep trenches can collapse. The standard reminds everyone involved to take the safety of the people working in deep foundations into account (4.3.1.4, note). Safety in excavations is covered by a separate part of the regulations, SANS 10400-G.

Sloping sites and steps

On a sloping site, the foundation may be stepped: it drops in level in steps instead of following the slope, which saves digging or filling. Where it steps, the ground behind the step must be drained and the step waterproofed (4.3.2.1.6). A step of more than 400 mm in height must be designed by a competent person under the general design route, not taken from the standard details (4.3.2.2.3).

Where a site is cut into by more than 0,75 m below the original ground level, or is marshy, or has a shallow water table, the competent person (geotechnical) must advise whether subsurface drains are needed (4.2.4).

Trenches for services

Services are the pipes and cables that run to the house, such as water, drainage and electricity. As far as practical, service trenches should not be dug parallel to the building within 1 500 mm of its outside walls (4.3.2.2.2). The standard does not give the reason, but the usual concern is that a trench dug close to and along the house disturbs the ground beside the foundation and gives water a path in.

Key words from this lesson

  • Setting out: marking the exact position of the walls on the ground.
  • Natural ground level (NGL): the ground surface before any digging or filling.
  • Founding depth: how deep the bottom of the foundation sits.
  • Founding horizon: the layer of ground the foundation rests on.
  • Geotechnical solution: improving the soil itself, designed by a competent person (geotechnical).

Clauses This Lesson Cites

Read them in your own copy of the standard. This lesson explains them in our own words and does not reproduce them.

SANS 10400-H 4.3.2.1.4SANS 10400-H Table 2SANS 10400-H Figure 5SANS 10400-H 4.3.1SANS 10400-H 4.3.2.2.2